Brand Name : Kacise
Model Number : KSS5F6
Place of Origin : shanxi xi'an
MOQ : 1
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1000 Pieces per Week
Delivery Time : 5 work days
Packaging Details : each unit has indicidual box and all boxes are packed in standard packages or customers requests available
Storage Temperature : -20-80℃
Operating Temperature : -20-60℃
Operating Humidity : 0-90%RH
Work Pressure : 0.8-1.2 atm
Supply Voltage : 12V
Maximum Operating Current : 120mA
Detection Range : 90-100%vol
Resolution : 1000ppm
Measurement Accuracy : ± 0.3% true value
T90 pipeline type : 20(500ml/min)S
Repeatability of Zero : Less than 0.2% FS
Repeatability of Range : Less than 0. 3%FS
KSS5F6 Infrared SF6 Purity Meter
Table 1 Version history
version | date | description |
V1.0 | 2016-10-12 | V1.0 released |
V2.2 | 2018-03-06 | Adapt product attribute modifications |
Table of Contents
SF6 gas is widely used as an insulating medium and arc extinguishing gas in power equipment, especially in high-voltage circuit breakers, transformers, transformers, capacitors, arresters, fuses, etc. Leakage occurs, equipment pressure decreases, insulation capacity is reduced; Pollute and destroy the atmospheric environment, increase the greenhouse effect; Accumulation in low-level spaces, resulting in accidents such as lack of oxygen in the brains of staff and even rapid asphyxiation; Under the influence of partial discharge, high temperature and other factors, SF6 gas will produce highly toxic decomposition substances such as SF4, SF2, SOF2, etc.
SF6 Purity Meter is a gas sensor module using NDIR infrared absorption detection principle. The concentration is determined according to the absorption of SF6 gas at 10.5um. The single-light source and dual-channel structure of MEMS light source, dual-channel pyroelectric detector and optical gas chamber are used to realize the reference compensation of the spatial dual optical path. Microprocessors perform signal acquisition, processing, and output, with temperature compensation and nonlinearity correction.
parameter | symbol | minimum | Typical values | maximum | unit | |
Storage temperature | Tstg | -20 | - | 80 | °C | |
Operating temperature | TA | -20 | 60 | °C | ||
Operating humidity | HA | 0 | 90 | % RH | ||
Work pressure | PA | 0.8 | 1.2 | atm | ||
Supply voltage | Vs | 11 | 12 | 30 | V | |
Maximum operating current | Iavg | 100 | 120 | 150 | mA | |
Detection range | Ra | 90-100 | %vol | |||
resolution | Resolution | 1000 | ppm | |||
Measurement accuracy | Acurracy | ± 0.3% true value | %vol | |||
T90 pipeline type | 20(500ml/min) | second | ||||
repeatability | zero | Less than 0.2% FS | ||||
Range | Less than 0. 3%FS | |||||
life span | 10 | year | ||||
Air intake method | Pipe-type | |||||
Warm-up time | 10min | |||||
Means of communication | UART,485,4~20mA | |||||
Operating temperature | T | The default is -20 degrees to 60 degrees, which can be customized by customers | ||||
baud rate | 9600, can be customized | |||||
Address number | The default is 20H, which can be modified by customers |
Unit: mm
LENGTH * WIDTH * HEIGHT (MM) = 80 * 43 * 40
See structural dimension drawing.
The sensor should be calibrated regularly, not more than 3 months is recommended.
Do not use the sensor for a long time in an environment with a high density of dust.
Please use the sensor within the range of the sensor's power supply.
1) Sensor name 2) Sensor range 3) Measurement accuracy, etc
For example, KSS5F6, 90%~100%, 2% accuracy, etc
Order information sheet | |||||
KSS5F6 | KSS5F6 CO2 concentration sensor | ||||
xxxx | The sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm. | ||||
2000 | Range 200ppm (default). | ||||
10000 | Range 10000ppm | ||||
50000 | Range 50000ppm | ||||
encode | The reaction speed is divided into two types: fast and slow | ||||
S | Slow (default). | ||||
Q | fast | ||||
encode | Baud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering. | ||||
Custom | Confirm the baud rate before ordering | ||||
2400 | 2400bps baud rate | ||||
9600 | 9600bps baud rate | ||||
19200 | 19200bps baud rate | ||||
38400 | 38400bps baud rate (default) | ||||
encode | Serial port protocol | ||||
Modbus-RTU | Standard Modbus-RTU protocol (default). | ||||
Modbus-ASCII | Standard Modbus-ASCII protocol | ||||
Modbus-Self | Modbus private protocol | ||||
KSS5F6 | -2000 | -S | -38400 | -Modbus-RTU |
URL: www.kacise.com
Tel: +86-29-62929722
Email: sales@kacise.com
Address: Tangyan South Road, Xi'an City, Shaanxi Province, China
Shorthand | Full name |
VOL | 1% VOL refers to 1% of the volume of a particular gas in air. |
PPM | 1PPM means that the volume of a specific gas in the air accounts for one millionth. |
O2 | Oxygen molecules |
LCD | LCD display |
RS485 | Asynchronous serial port 485 |
DC | direct current |
AC | Communication |
PVC | polyvinyl chloride |
![]() |
power equipment Infrared SF6 Purity Meter 90-100% Vol Images |